Optimization of the Method for Spectrofluorimetric Determination of Aluminum Impurities in Substances


Vishnyakov E.V. Tolstikova A.A. Generalova J.E. Kaldybaeva A.K. Terninko I.I.
2024Center of Pharmaceutical Analytics

Drug Development and Registration
2024#13Issue 118 - 25 pp.

Introduction. Evaluation of the content of impurities is the most important step in confirming the safety and efficacy in the quality control of the medicinal product. Aluminum, being an acceptable impurity in a number of pharmaceutical substances, can adversely affect the human body, as a result of which its content is normalized. The admixture of aluminum in the State Pharmacopoeia of the Russian Federation XV is determined by the spectrofluorimetric method using the ligand – 8-hydroxyquinoline in chloroform. In the present work, it is proposed to replace 8-hydroxyquinoline with the more accessible rutin, which also forms fluorescent complexes with metals. This approach involves the exclusion of the stage of extraction of the aluminum complex into chloroform from sample preparation, which improves the accuracy of the technique, and the replacement of chloroform has a positive effect on safety. Aim. To create an alternative approach for the spectrofluorimetric determination of aluminum impurities using rutin and potassium chloride as an active pharmaceutical ingredient. Materials and methods. The following substances and reagents were used as research materials: CRS of aluminum ion 1 mg/ml (LLC EKROSHIM, Russia), CRS of iron ion (II) 1 mg/ml (LLC EKROSHIM, Russia), CRS of zinc ion 1 mg/ml (LLC EKROSHIM, Russia), CRS of lead-ion 1 mg/ml (LLC EKROSHIM, Russia), CRS nickel-ion 1 mg/ml (LLC EKROSHIM, Russia), CRS copper-ion 1 mg/ml (LLC EKROSHIM, Russia), chromium (III) cation standard 1 mg/ml (imp., Sigma-Aldrich, USA) rutin (imp., Sichuan Guangsong Pharmaceutical Co., Ltd., China), ammonium acetic acid (imp., Molekula GmbH, Germany), glacial acetic acid (chemically pure, JSC Base No. 1 Himreaktivov, Russia), potassium chloride (pharmaceutical substance, LLC MZHR, Russia). The spectrofluorimetric study was carried out on an FL 6500 instrument (PerkinElmer Inc., USA). The aluminum impurity content was also evaluated using an Optima 8000 inductively coupled plasma atomic emission spectrometer (ICP AES) (PerkinElmer Inc., USA) and a Multi-Element Solution standard sample (PerkinElmer Inc., USA). Results and discussion. The approach given in the article eliminates the use of 8-hydroxyquinoline in chloroform and replaces it with rutin in 70 % ethyl alcohol. The aluminum-rutin complex has an excitation wavelength at 445 nm and an emission wavelength at 565 nm. The proposed method was tested on the substance Potassium chloride to assess the indicator Aluminum, the content of which should not exceed 0.0001 %. Method validation was carried out according to three parameters Specificity, Linearity and Limit of detection. Comparison of the data obtained was carried out using atomic emission spectroscopy, during which the relevance of the technique was proved. Conclusion. An ergonomic approach has been developed for the spectrofluorimetric determination of aluminum impurities using rutin with approbation on the substance Potassium chloride. The results obtained during the experiment were confirmed by the ICP AES method.

aluminum , atomic emission spectrometry , impurities , rutin , spectrofluorimetry , validation

Text of the article Перейти на текст статьи

Saint-Petersburg State Chemical and Pharmaceutical University, 14A, Prof. Popova str., Saint-Petersburg, 197022, Russian Federation
Asfendiyarov Kazakh National Medical University, 88/4, Tole Bi str., Almaty, 050000, Kazakhstan

Saint-Petersburg State Chemical and Pharmaceutical University
Asfendiyarov Kazakh National Medical University

10 лет помогаем публиковать статьи Международный издатель

Книга Публикация научной статьи Волощук 2026 Book Publication of a scientific article 2026