Advancing sanitary surveillance: Innovating a live-feed sewer monitoring framework for effective water level and chamber cover detections


Utepov Y. Neftissov A. Mkilima T. Shakhmov Z. Akhazhanov S. Kazkeyev A. Mukhamejanova A.T. Kozhas A.K.
30 March 2024Elsevier Ltd

Heliyon
2024#10Issue 6

Efficient sanitation system management relies on vigilant sewage surveillance to uphold environmental hygiene. The absence of robust monitoring infrastructure jeopardizes unimpeded conduit flow, leading to floods and contamination. The accumulation of harmful gases in sewer chambers, coupled with tampered lids, compounds sewer network challenges, resulting in structural damage, disruptions, and safety risks from accidents and gas inhalation. Notably, even vehicular transit is vulnerable, facing collisions due to inadequately secured manholes. The core objective of this research was to deconstruct and synthesize a prototype blueprint for a live-feed sewer monitoring framework (LSMF). This involves creating a data gathering nexus (DGN) and empirically assessing diverse wireless sensing implements (WSI) for precision. Simultaneously, a geographic information matrix (GIM) was developed with algorithms to detect sewer surges, blockages, and missing manhole covers. Three scrutinized sensors—the LiDar TF-Luna, laser TOF400 VL53L1X, and ultrasonic JSN-SR04T—were evaluated for their ability to measure water levels in sewer vaults. The results showed that the TF-Luna LiDar sensor performed favorably within the 1.0–5.0 m range, with a standard deviation of 0.44–1.15. The TOF400 laser sensor ranked second, with a more variable standard deviation of up to 104 as obstacle distance increased. In contrast, the JSN-SR04T ultrasonic sensor exhibited lower standard deviation but lacked consistency, maintaining readings of 0.22–0.23 m within the 2.0–5.0 m span. The insights from this study provide valuable guidance for sustainable solutions to sewer surveillance challenges. Moreover, employing a logarithmic function, TF-Luna Benewake exhibited reliability at approximately 84.5%, while TOF400 VL53L1X adopted an exponential equation, boasting reliability approaching approximately 89.6%. With this navigational tool, TF-Luna Benewake maintained accuracy within ±10 cm for distances ranging from 8 to 10 m, showcasing its exceptional performance.

Geographic information system , Internet of things , Sensors , Sewer chamber , Sewer monitoring

Text of the article Перейти на текст статьи

Department of Civil Engineering, L.N. Gumilyov Eurasian National University, Astana, Kazakhstan
Research and Innovation Center “Industry 4.0”, Astana IT University, Astana, Kazakhstan
The University of Dodoma, P. O. Box 259, Dodoma, Tanzania
Faculty of Mathematics and Information Technology, Karaganda Buketov University, Karaganda, Kazakhstan
Department of Technology of Industrial and Civil Engineering, L.N. Gumilyov Eurasian National University, Astana, Kazakhstan

Department of Civil Engineering
Research and Innovation Center “Industry 4.0”
The University of Dodoma
Faculty of Mathematics and Information Technology
Department of Technology of Industrial and Civil Engineering

10 лет помогаем публиковать статьи Международный издатель

Книга Публикация научной статьи Волощук 2026 Book Publication of a scientific article 2026