Purpose. Determination the proportion and burden of new-onset atrial fibrillation (AF) in patients with cardiac implantable electronic devices (CIED) and without prior AF and assessing the incidence of risk factors for stroke in patients with AF. Methods. The medical history of 111 patients with CIED with remote monitoring function were analyzed. AF diagnosed by the device was interpreted by an arrhythmologist and cases of significant AF were selected. The group of patients with and without AF was compared for several factors. To clarify the influence of risk factors on the duration of AF, all AF cases were divided into 3 categories depending on the AF burden per day. The first group included patients with an AF burden per day of 0.1% or less (n=10, (45.5%)), the second-from 0.3% to 12.2% (n=7, (31.8%)), and the third group-with 100% (n=5, (22.7%)). Patients with a burden of 0.2%, 12.3-99.9% were absent. Results. Newly diagnosed AF was registered in 19.8% of cases. The risk of stroke among these patients was high-2 [1; 3] points on the CHA2 DS2-VASc for men, and 3 [2,75; 3,75] points for women. Hypertension of 2 and 3 de-grees was recorded in all patients in the group with an AF burden of 100% per day. That significantly differed from the other 2 groups (p=0.043). In the group with an AF burden of 100%, the levels of NT-proBNP, D-dimer, and creatinine were significantly higher than in the other groups (p=0.037, p=0.031 and p=0.036, respectively). When analyzing the dependence of creatinine level on the presence of AF, the area under the ROC-curve was 0.653 with 95% confidence interval 0.528-0.779 (p=0.017). The proportion of right ventricular pacing in patients with ICD was higher in the group of patients with AF. Conclusion. AF occurs in 1/5 of patients with CIED. All patients with AF were potential candidates for anticoag-ulation due to their high risk of stroke. The daily burden of AF is positively correlated with the presence and degree of hypertension, as well as with markers of renal dysfunction, chronic heart failure, and thrombosis. Elevated creatinine levels are a predictor of AF.
Atrial fibrillation , Cardiac implantable electronic devices , Cardiac resynchronization therapy , Cardioverter defibrillator , Predictors of atrial fibrillation , Risk of stroke
Text of the article Перейти на текст статьи
NJSC Semey Medical University, 103 Abaya str., Semey, Kazakhstan
University of Cambridge, Trinity Lane, Cambridge, CB2 1TN, United Kingdom
National research cardiac surgery center, 38 Turan avenue, Nur-Sultan, Kazakhstan
NJSC Semey Medical University
University of Cambridge
National research cardiac surgery center
10 лет помогаем публиковать статьи Международный издатель
Книга Публикация научной статьи Волощук 2026 Book Publication of a scientific article 2026