Development of a method for cyclic voltametric determination of copper (II) ions in the composition of technological objects
Kuronboyev D. Faizullayeva M. Kutlimurotova N. Ismailova D. Tursunqulov J. Zulyarova N. Abdirahmonova A.
June 2025Iranian Chemical Science and Technologies Association
Chemical Review and Letters
2025#8Issue 3469 - 481 pp.
The use of heteroatom organic reagents, such as 5-(o-aminophenyl)-1,3,4-oxadiazole-2-thione, is important in developing selective and sensitive methods for the detection of Cu2+ ions. For this purpose, the use of cyclic voltammetric analysis, one of the electrochemical analysis methods, leads to high selectivity. Optimal conditions for CV determination of Cu2+ ion with 5-(o-aminophenyl)-1,3,4-oxadiazole-2-thione reagent: found that the linear dependence of the analytical signal on the metal ion concentration at an electrode scanning speed of 50 mV/s in ethyl alcohol solvent is 1.12-9.4 ppm/l. It has been proven that the formation of a complex between an organic reagent and a metal ion on the electrode surface occurs within 6 seconds using chronoamperometric and integral pulse amperometric methods. The half-wave potential of the organic reagent was found to be 0.48 V, and that of the complex formed by the Cu²⁺ ion was 0.65 V, with the potential shifting to the positive side proving the formation of a complex. From the CV of the complex, it was determined that the anodic and cathodic diffusion coefficients were Dox=2.59*10-6sm2/s; Dred=2,354*10-10sm2/s. The fact that the determination of copper(II) ion is not interfered with by Cd(II), Zn(II), and Pb(II) cations in a 1:1 ratio indicates that the developed method has a high selectivity. The developed method found a lower detection limit of copper(II) ion of 1.12 μg/ml. The accuracy of the method was compared with the atomic absorption method, and the calculated Students coefficient of 2.43 and Fishers value of 6.37, which are smaller than the values in the table, prove that the accuracy of the method is high. The developed CV method for determining Cu2+ ions was applied to the analysis of process water at the Almalyk Mining and Metallurgical Combine, and the relative standard deviation not exceeding 0.0145 indicates the high accuracy of the method.
5-(o-aminophenyl)-1,3,4-oxadiazol-2-thione , Amperometric titration , Analytical reagent , Chronoamperometry , Cu (II) ions , Cyclic voltammetry , Half-wave potential , Manual potentiostat , Students coefficient , Voltage
Text of the article Перейти на текст статьи
Khorezm Mamun Academy, Khiva, Uzbekistan
University of Korkyt Ata Kyzylorda, Kyzylorda, Kazakhstan
Department of Analytical Chemistry, Faculty of Chemistry, National University of Uzbekistan, Tashkent, Uzbekistan
Institute of Chemistry of Plant Substances, The Russian Academy of Sciences, Tashkent, Uzbekistan
Department of Pharmaceuticals and Chemistry, Faculty of Medicine, University of Alfraganus, Tashkent, Uzbekistan
Tashkent Institute of Chemical Technology, Tashkent, Uzbekistan
Department of Analytical Chemistry, National University of Uzbekistan, Tashkent, Uzbekistan
Khorezm Mamun Academy
University of Korkyt Ata Kyzylorda
Department of Analytical Chemistry
Institute of Chemistry of Plant Substances
Department of Pharmaceuticals and Chemistry
Tashkent Institute of Chemical Technology
Department of Analytical Chemistry
10 лет помогаем публиковать статьи Международный издатель
Книга Публикация научной статьи Волощук 2026 Book Publication of a scientific article 2026