Copper-Coated Spacer for Total Femoral Replacement in Recurrent Periprosthetic Joint Infection: A Case Report
Belokobylov A.A. Batpenov N.D. Balgazarov S.S. Serikbayev V.D. Krikliviy A.A. Plotnikov S.V. Turlybekuly A. Rimashevskiy D.V.
2021Eco-Vector LLC
Travmatologiya i Ortopediya Rossii
2021#27Issue 1175 - 182 pp.
Background. There are few cases of entire femur modular replacement with hip and knee joints in patients with periprosthetic joint infection (PJI) in literature. They report encouraging results in patients of elderly and senile age. We present case of a copper-coated femoral spacer implantation to 50-year-old patient with multiple PJI episodes and osteomyelitis of the entire femur. Clinical presentation. A 40-year-old male patient after resection of the proximal part of the right femur for fibrotic osteodysplasia underwent total hip arthroplasty with replacement of 15 cm of the femur. In December 2010 (20 months after implantation), instability of the femoral component developed, revision arthroplasty was performed with stem recementation. After 4 months, sinus tract formed in the area of the postoperative scar. After another 4 months, the head of the prosthesis was dislocated. In September 2011, the endoprosthesis components were removed and a unipolar cement spacer was implanted. The limb immobilized in a hip spica cast. Methicillin-sensitive S. epidermidis (MSSE) was detected in the preoperative joint aspiration puncture and periprosthetic tissues. After 3 months (December 2011), patient underwent revision total hip arthroplasty (25 cm defect was replaced). 5 years of PJI remission followed. In November 2016 after PJI recurrence the endoprosthesis was removed, and an articulating spacer was implanted. P. aeruginosa was detected in periprosthetic tissues. For the past 2.5 years there were periodically sinus tracts formations. In August of 2019 spacer’s migration resulted in an intercondylar fracture of the right femur. In September 2019, spacer was removed, and MSSE was detected in the surrounding tissues. An articulating cement spacer based on an oncological modular total femur copper-coated endoprosthesis was implanted. At each control examination during the year copper concentration in blood serum was determined, it did not exceed 900–1200 mcg/l. No local or systemic side effects were detected. The patient started working 3 months after surgery. After 6 months poor functioning sinus tract formed in the postoperative scar area in the lower third of the thigh. Eighteen months after the operation, the functional condition is satisfactory. Conclusion. The use of the copper-coated spacer based on modular total femur endoprosthesis with hip and knee joints in a patient with multiple PJI allowed to improve the function of the limb and reduce the severity of the infectious process. No local or systemic toxic effects of copper were detected.
articulating spacer , copper coating , periprosthetic fracture , periprosthetic joint infection , total hip replacement
Text of the article Перейти на текст статьи
Nursultan Scientific Research Institute of Traumatology and Orthopedics, Nur-Sultan, Kazakhstan
East Kazakhstan Technical University, Ust-Kamenogorsk, Kazakhstan
Nazarbayev University, Nur-Sultan, Kazakhstan
RUDN University, Moscow, Russian Federation
Nursultan Scientific Research Institute of Traumatology and Orthopedics
East Kazakhstan Technical University
Nazarbayev University
RUDN University
10 лет помогаем публиковать статьи Международный издатель
Книга Публикация научной статьи Волощук 2026 Book Publication of a scientific article 2026