Investigation of linear models for control of water flow and temperature in a water supply system


Asset A. Mansurova M. Zhmud V. Kopesbaeva A. Dzheksenbaev N.
July 2024Institute of Advanced Engineering and Science

Indonesian Journal of Electrical Engineering and Computer Science
2024#35Issue 1113 - 123 pp.

In some cases, the object model is a set of parallel models of the same general appearance, but with different parameters. The most common model is a model in the form of a serial connection of a first- or second-order filter and a delay link. An example is the water supply system of a large residential building or a group of houses. From the most general considerations, we can expect that such an object can be approximately described by a simpler model, replacing the sum of identical-looking models with different parameters with a single model of this type with averaged parameters, however, finding many parameters simply in the form of an average is, apparently, an unreasonable approach. It seems more reasonable to find the parameters by the approximating model by numerical optimization, in which the integral from the module or from the square of the deviation of the output signal of such a model from the output signal of the exact model is minimized when the test signal is applied. For linear models, the most reasonable test signal is a single step effect. This article tests this hypothesis and provides the results of this test.

Automation Control Modeling Optimization Water supply

Text of the article Перейти на текст статьи

Almaty University of Energy and Communications named after G. Daukeev, Almaty, Kazakhstan
Department of AI and Big Data, Al-Farabi Kazakh National University, Almaty, Kazakhstan

Almaty University of Energy and Communications named after G. Daukeev
Department of AI and Big Data

10 лет помогаем публиковать статьи Международный издатель

Книга Публикация научной статьи Волощук 2026 Book Publication of a scientific article 2026