Equation of motion of split conductor of anchor section at icing in wind flow


Abitayeva R. Bekbayev A. Dzhamanbayev M. Bayanbayev K. Aikimbayeva D.
November 2024Diponegoro university Indonesia - Center of Biomass and Renewable Energy (CBIORE)

International Journal of Renewable Energy Development
2024#13Issue 61005 - 1014 pp.

The relevance of the examined problem is connected with the necessity to develop measures to combat conductor galloping and the design of power transmission lines (ETL). The purpose of the research – to analyse statistical observation data on conductor galloping and apply a mathematical model to determine the parameters of galloping, to develop effective measures to combat conductor galloping and to improve the design of power lines. A sophisticated mathematical model was developed using Mathcad software to analyze conductor galloping in overhead power lines. This model, based on the equations of motion, predicts various galloping parameters under different conditions such as wind speed, span length, and initial mechanical stress. Time diagrams were constructed to represent linear and torsional motions, revealing correlations between amplitudes and frequencies. A comprehensive statistical analysis was performed on wire characteristics and split phase parameters to evaluate their impact on galloping patterns. Numerical methods, including the Runge-Kutta method, were employed to solve the equations and compute time-dependent behaviors. Results were visualized through graphs and diagrams to facilitate interpretation. The results revealed that conductor galloping occurs at wind speeds between 5 to 18 m/s, with significant occurrences at temperatures from 0°C to-10°C. The study identified that conductor galloping occurs within a wind velocity range of 5 to 13 m/s, predominantly with wind orientations between 30˚ and 90˚. The analysis showed that the frequency of galloping closely matches the natural oscillation frequency at low wind speeds but diverges with increasing wind speed and span length. These findings provide insights into the conditions under which conductor galloping is likely to occur and can inform design and operational strategies for overhead power lines.

conductor galloping , galloping frequency , linear and torsional motions , split phase , transmission line

Text of the article Перейти на текст статьи

Department of Power Engineering, Satbayev University, Kazakhstan
Department of Automation and Robotics, Almaty Technological University, Kazakhstan
Department of Electric Power Disciplines, Pavlodar Mechanical Engineering College, Kazakhstan

Department of Power Engineering
Department of Automation and Robotics
Department of Electric Power Disciplines

10 лет помогаем публиковать статьи Международный издатель

Книга Публикация научной статьи Волощук 2026 Book Publication of a scientific article 2026